Aramid 9352 (93/5/2 aramid blended)
Aramid 9352 English Translation
Aramid 9352 (also known as 93/5/2 or Aramid 3A) is the most widely used three-component blended ratio for fire-fighting and flame-retardant workwear:
93% Meta-Aramid (1313): Provides inherent flame retardancy, high temperature resistance and heat insulation; no molten drips and non-combustible when exposed to fire.
5% Para-Aramid (1414): Enhances tensile strength, tear resistance and wear resistance; stabilizes fabric structure under combustion.
2% Anti-static Fiber: Eliminates static sparks, suitable for explosion-proof scenarios such as oil & gas, petrochemical and power industries.
Common Names & Applications
Common Names: Aramid 3A, Nomex IIIA, 9352 Flame-Retardant Fabric, PetroChina Special Fabric.
Weight: Standard 200g/㎡, width 150cm.
Usage: Firefighting suits, flame-retardant workwear, arc flash suits, petrochemical / power protective clothing.
1. Basic Specifications
-
Composition: 93% Meta-Aramid (1313) + 5% Para-Aramid (1414) + 2% Anti-static Fiber
-
Fabric Weight: 180–210 g/㎡ (commonly 200 g/㎡)
-
Width: 150 cm
-
Weave: Plain / Twill / Ripstop (tear-resistant small square)
-
Color: Navy blue, orange red, royal blue, khaki, white, etc.
2. Flame Retardant Performance (Core)
-
Limiting Oxygen Index (LOI): ≥32%–35% (inherently flame retardant, non-flammable, no molten drips, self-extinguishing away from fire)
-
Afterflame / Afterglow: ≤2 s / ≤2 s (no residual embers)
-
Thermal Stability: Long-term temperature resistance 260°C; decomposition temperature ≥500°C
-
TPP (Thermal Protective Performance): ≥80 cal/cm² (NFPA 2112)
-
Standards: EN 11612, GA 10-2014, NFPA 2112
3. Mechanical Strength (Durability / Tear Resistance)
-
Breaking Strength (Warp / Weft): ≥800 N / ≥800 N
-
Tearing Strength (Warp / Weft): ≥200 N / ≥200 N (ripstop fabric up to ≥700 N)
-
Abrasion Resistance: ≥50,000 cycles (ISO 12947)
-
Dimensional Stability: Washing dimensional change ≤±1% (no shrinkage or deformation after repeated washing)
4. Anti-static Performance (Explosion-proof / Oil & Gas Scenarios)
-
Surface Resistivity: 10⁴–10⁵ Ω (IEC 61340, Class S)
-
Static Decay Time: <0.1 s (rapid static discharge, no spark generation)
-
Standards: EN 1149-1/5, GB 12014
5. Arc Flash Performance (Power Industry)
-
ATPV (Arc Thermal Performance Value):
150 g/㎡: 4.5–5.0 cal/cm²
200 g/㎡: 5.3–5.7 cal/cm² (lower than Level 1 arc suit standard ≥8 cal/cm²)
-
Application: Low-voltage power distribution and general industrial arc environments; not compliant with high-voltage Level 1 arc protection standards
6. Color Fastness & Weather Resistance
-
Washing Color Fastness: Grade ≥4–5
-
Rubbing / Light Fastness: Grade ≥4
-
Aging Resistance: UV-resistant, acid & alkali resistant, organic solvent resistant; flame retardant and anti-static properties permanent without attenuation
7. Applicable Standards
-
China: GB 8965.1-2020, GA 10-2014, GB 12014
-
EU: EN 11612, EN 1149, EN 531
-
USA: NFPA 2112, ASTM F1959 (ATPV)
Full Application Fields of Aramid 9352 (93/5/2 Aramid Blend)
With four core properties: permanent flame retardancy, high temperature resistance, anti-static, high strength & tear resistance, it is widely applied in high-risk industries, special workwear and public protection scenarios:
1. Petrochemical & Oil/Gas Industry
-
Flame-retardant and anti-static workwear for oilfield drilling, refineries and chemical parks
-
Uniforms for staff at gas stations, LNG stations and flammable & explosive warehouses
-
Core Advantages: Explosion-proof and anti-static, no molten drips in fire, prevents flash fire burns
2. Power & Energy Industry
-
Protective clothing for operation and maintenance of thermal power, hydropower, wind power and photovoltaic stations
-
General arc-flash workwear for substation and power distribution inspection
-
High temperature and radiation resistant auxiliary protective clothing for nuclear power plants
3. Firefighting & Emergency Rescue
-
Inner flame-retardant lining suits for forest fire fighters
-
Training uniforms for professional firefighters and standard workwear for emergency rescue
-
Rescue protective clothing for mine rescue teams
4. Metallurgy, Welding & High-temperature Working Conditions
-
High-temperature work clothing for steel, foundry, aluminum smelting and metallurgy industries
-
Flame-retardant labor protection clothing for welders, furnace workers and heat treatment workshops
-
Resists molten metal splashes, high temperature resistant, no shrinkage or deformation
5. Underground Mining Industry
-
Flame-retardant and anti-static miner uniforms for coal mines and non-coal underground mines
-
Protective workwear for tunnel engineering and underground operations
-
Complies with mine safety standards for flame retardancy and static explosion-proof requirements
6. Transportation & Rail Transit
-
Flame-retardant workwear for locomotive maintenance staff of high-speed trains and EMUs
-
Protective uniforms for dangerous goods operation in shipping, port and terminal areas
-
Anti-static and flame-retardant clothing for aviation ground staff and airport fuel depots
7. Military & Public Security
-
Flame-retardant training uniforms for armed police and public security on duty
-
Basic protective fabric for military logistics and field operations
-
High temperature resistant flame-retardant standard uniforms for security special service
8. Other High-end Industrial Labor Protection
-
Anti-static and flame-retardant suits for new energy battery factories (lithium battery, photovoltaic)
-
Workwear for production workshops of pharmaceutical, paint, ink and other hazardous chemicals
-
Custom standardized flame-retardant labor uniforms for large enterprise groups